BKGR Series Explosion Proof Floor Standing/Ceiling Type/Cabinet Air Conditioners

Plugs

It is Designed According to Gb3836; Adopting Special Craft Treating and Explosion Proof Treatment to Meet The Explosion Proof Requirements.

The Pipeline Connection of Explosion Proof Air Conditioner is Normal. Electrical Connection Shall Meet the Requirements of Installation Technology of Explosion Proof Electrical Apparatus. The Power Separately be LED in the Indoor and Outdoor Machines Via Explosion Proof Control Panel.

Contact us for quote

Email: sales@fix-it.ng
Tel: +234-902-111-1193

Product Details

Plugs

Mounting Schematic and Dimensions

Features

On the Base of Famous Brand Air Conditioner. It is Designed According to Gb3836; Adopting Special Craft Treating and Explosion Proof Treatment to Meet The

Explosion Proof Requirements;

The Pipeline Connection of Explosion Proof Air Conditioner is Normal. Electrical Connection Shall Meet the Requirements of Installation Technology of Explosion Proof Electrical Apparatus. The Power Separately be LED in the Indoor and Outdoor Machines Via Explosion Proof Control Panel;

Full Sets of Technical Documents and Instructions are Attached to All Air Conditioners When Out of Factory, Please Install and Use According to Instructions Strictly;

With Compact Structure and Good Appearance, Easy to Install and Maintain;

Steel Pipe or Cable Wiring.

Model Code


Ordering References

Please Specify Model Code When Order. The Original Model is Gree Air Conditioner. Other Requirements, Please Indicate;

Please According to Space and Refer to the Selection Table to Choose Air Conditioner;

If the Length of Connection Pipe is over Standard, Please Indicate;

The Air Conditioner with 380V Has Matched Explosion Proof Power Sources Switch (Explosion Proof Circuit Breaker) When Delivery;

Can be Equipped with Electric Heater; If Need, Please Indicate;

It Shall be Installed by Specialist;

For Example: If Need Explosion Proof Floor Standing Air Conditioners, Refrigerating and Heating Type, Refrigerating Power is 5P, 380V, the Model Shall be BKGR-120/380;

Application

  • Designed for Explosive Atmospheres Zone 1 and Zone 2;
  • Designed for IIA, IIB, IIC Groups Explosive Atmospheres;
  • Designed for Temperature Classifications T1~T4;
  • Designed for Explosive Hazardous Locations Such as Oil Refinery, Storage, Chemical, Pharmaceuticals, Military Industries, Etc.

Selection Table

Technical Parameters

Compliance with: GB 3836.1, GB 3836.2,GB 3836.3,GB 3836.4,GB 3836.8,IEC60079-0, IEC60079-1,IEC60079-7,IEC60079-11,IEC60079-15

Rated Voltage: AC220/380V

Ex marks: Ex d e ib mb IIC T4 Gb

Instruction of Main Components

Solution

On the Base of Famous Brand Air Conditioner, the Explosion Proof Indoor and Outdoor Units are According to Gb3836;

Outdoor Unit: Adopt Special Craft on the Internal Electric Control Components , Compressor, Fan, and Protective System.

The Outdoor Dimension and Mounting Type are Same to Original Outdoor Air Conditioner;

Indoor Unit: Dissemble the Internal Electric Components, Adopt Explosion Proof Design to Make an Independent Explosion Proof Control Panel with Manual Function, the Size of Control Panel Refers to Table Selection;

Explosion Proof Indoor and Outdoor Units Adopt Several Explosion Proof Treatment Structure, Weak Electricity Control Parts Adopt Intrinsic Safety Explosion Proof Circuit.

Explosion Proof Treatment on Special Air Conditioner Can be as Per Request. For Example: Water Chillers, Chilling System, Central and Special Air Conditioner Devices, We Will Design Scheme for Users’ Approval. If Necessary, We Will Apply National Explosion Proof Test for the Property.